Deck permits in
Riverton.
Riverton states its frost depth precisely — bottom of footing to finished grade — and takes its snow load per address.
Do you need a permit to build a deck in Riverton?
Yes for any deck of a usable size. Riverton enforces the 2021 IRC including Appendices AE and AQ, so a deck avoids a permit only under the full IRC §105.2 exemption — free-standing, 200 sq ft or less, floor no more than 30″ above grade, unattached to the dwelling and not serving an exit door.
Source: Riverton City Building Codes and Design Criteria (effective 1 July 2026). Read from the city’s own document and verified .
The numbers your drawings have to use
These come straight from the city’s published design criteria. They are what a plan reviewer checks a deck against.
| Criterion | Value |
|---|---|
| Ground snow load | No city figure — USU snow load site, per address |
| Frost depth | 30 inches minimum, bottom of footing to finished grade |
| Wind load | 105 mph, Exposure C |
| Seismic zone | D |
| Residential code | 2021 IRC, Appendices AE and AQ |
| Ice barrier underlayment | Required to 24 inches inside the home |
Riverton is precise about the one measurement people get wrong: 30 inches from the bottom of the footing to finished grade. Not to the top of a slab, not to existing dirt — to finished grade, which is where the ground will be when the job is done. If your deck sits where the yard is about to be regraded, that is the level that counts.
Riverton’s code updates itself
Riverton City Code 15.10.010 adopts whatever version of the I-codes the State of Utah has most recently adopted, and says that future state adoptions automatically update the city’s code. There is no separate city vote to track.
The practical effect for a homeowner: a handout printed a few years ago may name an older code edition than the one your plan reviewer is working from. It is a good reason to confirm rather than rely on a PDF, including this page.
No Riverton snow number
Like several Salt Lake County cities, Riverton publishes no ground snow load of its own and sends you to the USU Utah Ground Snow Load site for the address. Wind is 105 mph at Exposure C — open terrain, the same figure the MSD townships and West Jordan use, and lower than Salt Lake City’s 115 mph.
Who to talk to at the city
Riverton City Building Division — building codes and design criteria. Flood hazard is checked against the FEMA map service centre rather than a city map.
Measure frost depth to finished grade, not to today’s dirt. On a new build or a yard being regraded around the deck, those are different levels, and the footing inspection is done against the finished one.
We handle this part
The USU snow load for your address, footings to 30 inches below finished grade, 105 mph Exposure C sizing, drawings, submission and inspections — in our quote, not an extra.